03/27/2012 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
03/01/2012 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) CLOSET FLANGES TO EXTEND 1/4" ABOVE FINISHED FLOOR |
|
01/23/2012 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) GAS PRESSURE TEST OK 2) ABS DWV THRU ROOF OK 3) PEX OK 4) NEED TO SEE CLOSET FLANGE |
|
01/17/2012 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) PLEASE POST YOUR ADDRESS 2) WATER TEST IS THRU THE ROOF 3) HORIZONTAL X HORIZONTAL CHANGE OF DIRECTION TO BE A SWEEP 4) ABS MAY NOT BE DIRECTLY EMBEDDED IN CONCRETE 5) PLUMBERS TAPE NOT APPROVED SRAP-NOR ABS SHIMS 6) SUPPORT VERTICAL PIPE 7) WATER PIPING OK |