Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T11CM02899
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/08/2012 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
05/25/2012 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) 4" PVC DRAIN FOR FUTURE TENANT, NEXT TO HAIRCARE OK TO BACKFILL 2) TRENCH DRAIN AT G.M. VESTIBLE CART STORAGE OK TO COVER |
|
05/23/2012 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) TRENCH DRAIN AT G.M. VESTIBULE OK TO COVER 2) TRENCH DRAIN INSTALLED AT CART STORAGE AND TESTED OK 3) PHARMACY PLUMBING OK TO COVER |
|
05/21/2012 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) SOIL PIPING FROM GRID LINE D TO HCS CONNECTION AND BRANCHES TO COL 7.4 WITH TEST OK |
|
05/18/2012 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1) PIPE SIZES AT SS SEWER TO MATCH PLANS |
|
05/17/2012 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* | |
05/10/2012 | PLUMBING - ROUGH, SOIL | Partial Approval | 1) WATER TEST FOR DWV, OR PARTIAL, IS MINIMUM TEN FEET HEAD 2) VENTS BELOW THE FLOOD RIM TO HAVE 2 PERCENT PITCH 3) AT HAIR CARE UNDER FLOOR OK TO COVER 4) 4" SS SEWER EXTENDED TO POC WITH 6" OK |
|
05/09/2012 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* | |
05/03/2012 | PLUMBING - ROUGH, SOIL | Partial Approval | 1) SANITARY SEWER, FUTURE TENANT STUBS AND OTHER BRANCHES TO COLUMN G-7 AT FRONT OF STORE OK TO COVER | |
04/27/2012 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) SANITARY (CWV) SEWER AND GREASE WASTE BRANCH PIPING EAST HALF OF BLDG (GROCERY AREA) OK TO COVER COLUMN LINE #4 EAST AND #A-K |
|
04/26/2012 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) NORTH SIDE SANITARY WASTE UNDER SLAB TEST OK |
|
04/20/2012 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) GW DELI AND BAKERY |
|
04/17/2012 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1) CORRECTIONS FROM 04/13/12 MADE OK. OK TO COVER |
|
04/13/2012 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) GROCERY CASES BETWEEN COLS 1 AND 2 TRAPS WITH REDUCERS OK EXCEPT 1 LEAK 2) FS1 OFF OF 6" MAIN; BRANCH CONNECTION REQUIRES A CORRECTION 3) CONNECT BRANCH TO MAIN HORIZONTALLY 4) UPC 910.5 DOES NOT ALLOW VERTICAL CONNECTION 3) |
|
04/11/2012 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) RECEIVING DWV #7 AND AQUARIUM SOIL WITH TEST OK |
|
04/05/2012 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) 6" X 300' AIR TEST FOR 5 MINUNTES AND 40 SECONDS WITH NO DROP OK 2) 6" X 140' AIR TEST FOR 5 MINUTES AND 40 SECONDS WITH NO DROP OK 3) PVC BLDG DRAIN FOR BREAKROOM OK 4) FROM BATHROOM TO BREAKROOM OK |
|
03/27/2012 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) SANITARY WASTE FROM AUTO CARE AND GREASE INTERCEPTOR TO COLUMN #7 OK TO COVER 2) WATER TEST 1 RISER TO 10' |
|
03/23/2012 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* | |
03/15/2012 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) GREASE WASTE UNDER BLDG OK TO COVER 2) C.W.V. IN GROCERY AREA MAIN ONLY 3) BRANCHES TAKEN OFF OF MAIN AT 45 DEGREE OK PER RON BOOSE |
|
03/14/2012 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1) SEE 2006 UPC ILLUSTRATED TRAINING MANUAL CWV 2) CWV SYSTEM IS DESIGNED TO BE FLAT, WITH DRAINAGE ALONG THE BOTTOM AND VENTING ALONG THE TOP OF THE PIPE. ALL BRANCH CONNECTIONS TO BE MADE FROM THE SIDE AND ONE 45 DEGREE OFF SET ALLOWED ALONG THE BRANCH TO MINIMIZE TAIL PIECE LENGTH 3) GREASE WASTE MAIN TO WITHIN 10' OF EXTERIOR WALL 4) OK TO COVER ? |
|
03/09/2012 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* |