Permit: T11CM02454

Parcel: 12512080A


Addresses:

3360 E SPEEDWAY BL

Inspection Status: Approved

Inspection History: PLUMBING - PROGRESS

Date Description Inspector Results Comments
11/22/2011 PLUMBING - PROGRESS Approved IVRS - Inspection :*
10/18/2011 PLUMBING - PROGRESS Not ready for Inspection IVRS - Inspection :*
1) PROVIDE A VENT FOR P TRAP AHEAD OF FLOW CONTROL VENT AS REQUIRED BY 1014.5 AND 1002.1-SEE ILLUSTRATION PROVIDED
2) ABS AND PVC TRANSITION GLUE IS NOT APPROVED FOR USE INSIDE, USE A BAND
3) CLEANOUT PLUG HS SHALL BE LISTED TO RECEIVE A SCREW
4) SECURE HOT CASE DRAIN WITH APPROVED PLUMBING SUPPORTS