Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/15/2011 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 09/14/2011 | PLUMBING - FINAL | Not ready for Inspection | 1) GAS APPROVED SUBJECT TO MEHCANICAL INSPECTORS APPROVAL OF FLEX CONNECTORS. HAVE MECH INSPECTION LEAVE GAS CARD 2) OPEN HOLES IN THE CONCRETE CONSTITUTES A HAZARD. RE-INSTALL THRU FRANK PATTERN CLEANOUT COVERS AND RECALL 03090 |
|
| 09/12/2011 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) UNABLE TO ACCESS IVR SYSTEM 2) 2 WAY CLEANOUT, WHERE BLDG DRAIN MEETS, BLDG SEWER MISSING PARTS 3) FLEX CONNECTORS FOR ROOF TOP UNITS MUST BE SIZED CORRECTLY |
|
| 09/09/2011 | PLUMBING - FINAL | Not ready for Inspection | 1) REQUIRES 15" FROM CENTER LINE TO SINK WALL OR OBSTRUCTION ON URINAL 2) REQUIRE 15" FROM CENTER LINE TO SIDE WALL OR OBSTRUCTION ON WATER CLOSET 3) GAS OK |