Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T10PL01067
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/17/2011 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
04/05/2011 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
08/20/2010 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE A WATER HEATER THAT IS APPROVED FOR MANUFACTURED OR MOBILE HOME USE 2) PROVIDE A FULL PORT FULL SIZE 3/4" COLD WATER SHUT OFF VALVE SERVING ONLY THE WATER HEATER 3) PROVIDE COPPER PIPING MINIMUM 18" INTO AND OUT OF WATER HEATER BEFORE TRANSITION TO PEX 4) PROVIDE CORRECT WATER HEATER VENTING TERMINATING MINIMUM 3' ABOVE TOP OF COOLER WHEN WITHIN 10' OF COOLER INTAKE |