Case: T10FR00783

Parcel: 11618250A


Addresses:

1002 W CONGRESS ST

Inspection Status: Correction Required

Inspection History: VIOL - MEANS OF EGRESS

Date Description Inspector Results Comments
04/21/2010 VIOL - MEANS OF EGRESS Correction Required IFC 1008.1.8.4 Bolt locks. Manually operated flush bolts or surface bolts are not permitted.

_____1. Remove the slide bolt from the south entrance door.

_____2. Remove the slide bolt from the North door by the office.
04/21/2010 VIOL - MEANS OF EGRESS Correction Required IFC 1008.1.8 Door operations. Except as specifically permitted by this section egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort.

_____1. Remove the double-keyed lock from the North exterior door.

_____2. Remove the locking bar and hardware from the North exterior door.