Case: T10FR00369

Parcel: 137031110


Addresses:

5244 S NOGALES HY

Inspection Status: Correction Required

Inspection History: VIOL - MEANS OF EGRESS

Date Description Inspector Results Comments
02/17/2010 VIOL - MEANS OF EGRESS Correction Required IFC 1004.3 Posting of occupant load. Every room or space that is
an assembly occupancy shall have the occupant load of the
room or space posted in a conspicuous place, near the main exit
or exit access doorway from the room or space. Posted signs
shall be of an approved legible permanent design and shall be
maintained by the owner or authorized agent.

_____1. Post the occupant load on a clearly visible sign on the wall by the main entrance.
02/17/2010 VIOL - MEANS OF EGRESS Correction Required IFC 1008.1.8.4 Bolt locks. Manually operated flush bolts or surface bolts are not permitted.

_____1. Remove the slide bolt from the southwest EXIT door.

_____2. Remove the slide bolts from the Northeast EXIT door.
02/17/2010 VIOL - MEANS OF EGRESS Correction Required IFC 1008.1.9 Panic and fire exit hardware. Where panic and
fire exit hardware is installed, it shall comply with the following:
1. The actuating portion of the releasing device shall
extend at least one-half of the door leaf width.
2. The maximum unlatching force shall not exceed 15
pounds (67 N).
Each door in a means of egress from a GroupAor E occupancy
having an occupant load of 50 or more and any Group
H occupancy shall not be provided with a latch or lock
unless it is panic hardware or fire exit hardware.
Exception:Amain exit of a Group Aoccupancy in compliance
with Section 1008.1.8.3, Item 2.
If balanced doors are used and panic hardware is
required, the panic hardware shall be the push-pad type and
the pad shall not extend more then one-half the width of the
door measured from the latch side.

_____1. The Northeast EXIT double doors shall have panic hardware installed.
02/17/2010 VIOL - MEANS OF EGRESS Correction Required IFC 1028.2 Reliability. Required exit accesses, exits or exit discharges
shall be continuously maintained free from obstructions
or impediments to full instant use in the case of fire or
other emergency when the areas served by such exits are occupied.
Security devices affecting means of egress shall be subject
to approval of the fire code official.

IFC 1008.1 Doors. Means of egress doors shall meet the requirements
of this section. Doors serving a means of egress system
shall meet the requirements of this section and Section 1017.2.
Doors provided for egress purposes in numbers greater than
required by this code shall meet the requirements of this section.

IFC 1008.1.2 Door swing. Egress doors shall be side-hinged
swinging.Doors shall swing in the direction of egress travel where
serving an occupant load of 50 or more persons or a Group
H occupancy.

_____1. Install an EXIT door equiped with panic hardware in the fenced area on the Northwest corner of the building, so occupants can exit from the outside fenced area.