Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - UNDERGROUND
Permit Number - T10CM03257
Inspection Description - ELECTRIC - UNDERGROUND
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/05/2012 | ELECTRIC - UNDERGROUND | Approved | ||
06/04/2012 | ELECTRIC - UNDERGROUND | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) USE APPROVED CONNECTIONS TO BOND WIRE |
|
05/30/2012 | ELECTRIC - UNDERGROUND | Partial Approval | IVRS - Inspection :* 1) OK #8 BONDS FLAT DECK FOR WATER SPLASH PAD 2) COOL DECK BOND TO BE 18"-24" FROM EDGE-BOND ALL METAL WITHIN 5' OF EDGE |
|
04/05/2012 | ELECTRIC - UNDERGROUND | Partial Approval | RUN FROM NEW SERVICE TO PUMP HOUSE AND TO RESTROOM BLD OK | |
03/23/2012 | ELECTRIC - UNDERGROUND | Partial Approval | PUMP HOUSE OK. WADING POOL BONDING OK REQUIRED, BUT NOT SHOWN ON PLANS IS AN EQUIPOTENTIAL BONDING GRID PER NEC 680.26(C) AT SPLASH PAD. |
|
02/08/2012 | ELECTRIC - UNDERGROUND | Partial Approval | IVRS - Inspection :* | |
02/08/2012 | ELECTRIC - UNDERGROUND | Partial Approval |