Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/27/2011 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 01/26/2011 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) HORIZONTAL X HORIZONTAL CHANGE OF DIRECTION TO BE A SWEEP 2) I.W. WASTE OVER FIVE FEET TO BE DIRECTLY TRAPPED 3) PROVIDE METHOD OF STERILIZATION 4) PROVIDE LISTING FOR STUDER VENT TO BE INSTALLED HORIZONTALLY |
|
| 12/16/2010 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) REVIEWED INSPECTION PROCESS WITH OWNER 2) HAVE LICENSED PLUMBER REVIEW PLAN, OPEN UP AREAS COVERED WITHOUT INSPECTION 3) INDIRECT WASTES MAY NOT BE COMBINED 4) SINKS AND 2 COMP OF 3 COMP SINK TO DRAIN DIRECTLY INTO S.S. 5) BACK FLOW PROTECTION, BACK FLOW CERT, CLEAN BACTERIA REPORT AND METHOD OF STERILIZATION 6) PROVIDE ISOMETRIC FOR WASTE PIPING AT NEW BAR AREA |