Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/26/2011 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* 1) SCREEN WALL TOPPED OUT AT 7' 4" OK TO GROUT AND CAP |
|
| 05/25/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) EAST SITE WALL 1ST LIFT |
|
| 05/24/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) NORTH AND WEST SITE WALL 1ST LIFT |
|
| 02/11/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) BLDG #2 GL: A (SOUTH WALL) ROOMS #203 AND 204 16'8"-20'4"; SOUTH WALL ROOMS 209, 221 (GL:A) 16'8"-20'4": ROOM #212, EAST WALL GL 3 AT 16'8"-20'4" OK TO GROUT PROGRESS AREAS |
|
| 02/10/2011 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
| 02/02/2011 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* 1) NOT READY PER CONTRACTOR |
|
| 02/01/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* PARTIAL TO POUR AS MARKED ON PLAN |
|
| 01/31/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) AS MARKED ON PLAN |
|
| 01/28/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) NORTH WALL TOP OUT, EAST WALL ROOMS 225-234 TOP OUT |
|
| 01/27/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) WEST WALL ROOM 200, EAST WALL ROOM 200-205, SOUTH WALL ROOMS 203 AND 204 2) VERIFY THAT L + 4 AT 45 DEGREE ANGLE CORNER DOES NOT NEED ? UPS |
|
| 01/26/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) WEST WALL ROOM 224-234 4TH LIFT, EAST WALL ROOM 205-209, 225-234 3RD LIFT, SOUTH WALL ROOMS 209 & 225 3RD LIFT AND EAST WALL ROOM 212 3RD LIFT |
|
| 01/24/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) AS MARKED ON 1/2 SET-SPECIAL INSPECTED |
|
| 01/20/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 3RD LIFT AS MARKED ON 1/2 SET 2) SPECIAL INSPECTION ON SITE |
|
| 01/18/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) ROOM #200-209; 212; 225-234 EASTWALL 200, 223, 205, 224 N WALL 2ND LIFT SOUTH WALL 209 SPECIAL INSPECTION |
|
| 01/14/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) CMU WALLS AT 8'-4" GL: 3/G-I; F/3-5 OK TO GROUT |
|
| 01/13/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 2ND LIFT AS MARKED ON PLAN 2) SPECIAL INSPECTION |
|
| 01/12/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 1ST LIFT COMPLETE |
|
| 01/11/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 1ST LIFT COMPLETED 1-10 |
|
| 01/10/2011 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 1ST LIFT |
|
| 11/30/2010 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* |