Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - ABOVE CEILING
Permit Number - T10CM01503
Inspection Description - ELECTRIC - ABOVE CEILING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/04/2012 | ELECTRIC - ABOVE CEILING | Approved | IVRS - Inspection :* | |
08/24/2011 | ELECTRIC - ABOVE CEILING | Partial Approval | RECEIVED CHECK #120 FOR 165.00 | |
08/09/2011 | ELECTRIC - ABOVE CEILING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FINISH ELECTRIC ROOM: CIRCUITS, CONDUIT SUPPORTS, INVERTER, INVERTER SYSTEM 2) FINISH: WALL SWITCHES, RECEPTS, WATER FOUNTAINS AND LIGHTING 3) BOXES MORE THAN 1/4" IN NON COMBUSTIBLES 314.20 OR 1/8" 314.21 4) REMOVE TEMP CIRCUITS 5) EMERGENCY EGRESS LIGHTING NOT WORKING 6) LABEL AIR HANDLER DISCONNECTS 7) AT CHILLER LOOSE FITTINGS AND BOXES-ALSO SUBMIT SEAL TITE PER CODE FINISHING RECEPTS 8) FINISH ELECTRIC WORK 9) TRENCHES HAVE OCCUPIED SPACES AND ROOMS WITH BELONGINGS |
|
08/08/2011 | ELECTRIC - ABOVE CEILING | Partial Approval | IVRS - Inspection :* 1) SUPPORT VDV CABLING 725.3 & 8, 760.3 & 24, 800.3 & 24, 300.11 2) SUPPORT FLEX CONDUITS 12" + 6' OF LONGER THAN 4' |
|
08/06/2011 | ELECTRIC - ABOVE CEILING | Partial Approval | IVRS - Inspection :* | |
08/05/2011 | ELECTRIC - ABOVE CEILING | Partial Approval | IVRS - Inspection :* 1) OK HALL 123 2) OK CHILLER TO ENERGIZE 3) RECEIVED MONEY ORDER #14-365880478 FOR $165.00 |
|
07/29/2011 | ELECTRIC - ABOVE CEILING | Partial Approval | IVRS - Inspection :* 1) BLDG 300 CEILINGS OK |
|
07/25/2011 | ELECTRIC - ABOVE CEILING | Partial Approval | IVRS - Inspection :* | |
07/19/2011 | ELECTRIC - ABOVE CEILING | Partial Approval | IVRS - Inspection :* 1) CHECK BOX FILL 2) OK CEILINGS 107,110,111,112,115,116,121 AND 122 |
|
07/14/2011 | ELECTRIC - ABOVE CEILING | Partial Approval | IVRS - Inspection :* | |
07/13/2011 | ELECTRIC - ABOVE CEILING | Not ready for Inspection | IVRS - Inspection :* OK 3" + 4" PVC AT SERVICE OK ABOVE CEILING 401,402,405,406,505,506 |
|
07/08/2011 | ELECTRIC - ABOVE CEILING | Partial Approval | IVRS - Inspection :* 1) OK 501 & 502 |
|
05/25/2011 | ELECTRIC - ABOVE CEILING | Partial Approval | IVRS - Inspection :* 1) OK HARD LIDS 112, 113 & 408 |
|
05/19/2011 | ELECTRIC - ABOVE CEILING | Partial Approval | IVRS - Inspection :* 1) BUILD 300, NO MORE 360 DEGREE IN RUN FIRE ALARM 2) BUILD 300 JUNCTION BOXES TO BE ACCESSIBLE 3) BUILD 200 NO MORE THAN 360 DEGREE IN RUN FIRE ALARM 4) OK WALL RECEPTION, 103 AND 104 5) OK SOFFITS HALL ? 6) OK HARD LIDS 503, 504, 403, 404, 303, 304, 203 AND 204 |
|
05/05/2011 | ELECTRIC - ABOVE CEILING | Partial Approval | IVRS - Inspection :* |