Permit: T10CM01503

Parcel: 10601247B


Addresses:

266 E PASTIME RD

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
01/04/2012 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
11/08/2011 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) OK WALL REDO WEST LOUNGE OLD BLDG
07/27/2011 ELECTRIC - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1) ANSWERED QUESTIONS ABOUT CT CAN
07/26/2011 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) FINISH WORKING AREA AT SES-OK FOR TEMP USAGE
2) NOTE: BOND RISER AND SERVICE NIPPLE 250.92
3) OK LAST 10' INTO TEP TRANSFORMER
07/25/2011 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) DISCONNECT TO BE ACCESSIBLE ROOM 103 AND WORKING SPACE
2) JUNCTION BOXES TO BE ACCESSIBLE HALL 123
3) OK ABOVE CEILING ROOM 105
4) OK WALLS 603 & 600
07/21/2011 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) PROVIDE PHYSICAL PROTECTION FROM SHARP METAL EDGES VDV CABLING
2) OPEN WALL ROOMS MPR FOR INSPECTION
3) EXISTING MAIN SWITHBOARD HAS CODE COMPLIANT ISSUES 110.26 (A) (1) & (2)
4) OK WALLS CLASSROOM 1,2 & 3
05/19/2011 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
04/29/2011 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
04/22/2011 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) BLDG 100 CHILLER AND OUTLETS OK
04/18/2011 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
04/12/2011 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :* NO MORE THAN 360 DEGREES IN CONDUIT RUNS
OK WALLS 501, 502, 505-507
03/16/2011 ELECTRIC - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1) OK LAST LIFTS
2) NEED FORMAN ON SITE
03/08/2011 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) OK PVC CONDUITS
2) UNDER ELECTRIC ROOM #309
03/02/2011 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
02/28/2011 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
12/01/2010 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) OK HOME RUNS SE. AREA TO ELECTRIC ROOM AND CONUITS IN MASONRY WALLS EAST ROOMS