Permit: T10CM01503

Parcel: 10601247B


Addresses:

266 E PASTIME RD


Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Permit Number - T10CM01503

Inspection Description - EXCAVATION/LAYOUT REBAR & ZON

Inspection Status - Approved

Date Description Inspector Results Comments
12/30/2011 EXCAVATION/LAYOUT REBAR & ZON Approved
10/18/2011 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) MEMORIAL WALL FOOTING OK TO POUR
08/26/2011 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) COURT YARD FOOTINGS SCREEN WALL-BASKETBALL WALL COURT AREA (NW) DETAIL #5-6, PAGE L-7, DUMPSTER ENCLOSURE FOOTING, DETAIL #N21, PAGE SD03-OK TO POUR PROGRESS AREAS
08/05/2011 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) 8 EACH C12-12, F 5-6 COLUMN FOOTINGS
08/04/2011 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
08/02/2011 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) 22 EACH C12-12/F 5-6 COLUMN FOOTINGS OK TO POUR PROGRESS AREA
08/01/2011 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) 8 EACH C-12-12, F6-3; DETAIL #408 OK TO POUR FOOTINGS
07/01/2011 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) 6 COLUMN FOOTERS FOR CANOPY
04/12/2011 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :* MECHANICAL EQUIP AREA; FOOTINGS COT DETAIL #9 - OK TO POUR FOOTINGS
03/10/2011 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) EAST WALL AT HALLWAY #124; SOUTH WALL 308-309 OK TO POUR FOOTINGS
02/22/2011 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) FOOTINGS FOR W3 WALL: HALLWAY 300 W, #123-OK TO POUR FOOTINGS
02/16/2011 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) ROOM 206 & 207
02/10/2011 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) FOOTING FOR ROOM 123B OK TO POUR
01/31/2011 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
01/27/2011 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
1) NOT READY
01/24/2011 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) CONTINOUS FOOTINGS CLASSROOM #201 AND 202 OK TO POUR
12/27/2010 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) EAST SIDE OF BLDG 300
12/21/2010 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) BLDG #100 & 200 G;: 6/E-A, A/6-8, A/8-11 EXCEPT ENTRY AREA 8.5-9; 10.5/A-E, B/11-13, 13/B-C; C/13-14, 14/C-E, E/8-12 OK TO POUR PROGRESS AREAS
12/13/2010 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) INTERIOR FOOTING ROOM 302
12/10/2010 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
1) NOT READY PER CONTRACTOR
11/30/2010 EXCAVATION/LAYOUT REBAR & ZON Partial Approval 1) BLDG #600, SOUTH FOOTING; 6 AT COLUMN FOOTINGS; DETAIL #407A OK TO POUR
11/22/2010 EXCAVATION/LAYOUT REBAR & ZON Partial Approval 1) INTERIOR FOOTINGS
11/16/2010 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) BLDG 400
10/27/2010 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) CLASSROOM BLDG #500; CONTINOUS
2) FOOTINGS (WF1, WF2); WING WALL AT GL: F.5/17-21 OK TO POUR PROGRESS AREAS: WALL REINFORCING W1-W3
10/19/2010 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) GL-K/7-10; J.5/7 OK TO POUR PROGRESS AREAS
10/15/2010 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
GL E/1-2, 2/D-8-E, 1/D-E, H/5-10.5, 10.5/D.7-K, 7/H-3, E/10.5-17, 11/D.7-E, J/10.5-17, 17/F-J
10/14/2010 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*