Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T10CM01281
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/26/2011 | PLUMBING - ROUGH, SOIL | Approved | ||
10/28/2010 | PLUMBING - ROUGH, SOIL | Partial Approval | SUMP TANK INSTALLATION OK FOR BACKFILL. STILL NEED TO SEE DISCHARGE PIPE INSTALLATION. DO NOT COVER VENT FROM INTERCEPTOR UNTIL IT HAS BEEN TESTED AND INSPECTED |
|
09/15/2010 | PLUMBING - ROUGH, SOIL | Partial Approval | TEST ON INTERCEPTOR OK | |
08/17/2010 | PLUMBING - ROUGH, SOIL | Partial Approval | OK TO COVER BATHROOM GROUP AND OUTSIDE DRAIN PIPING. KITCHEN ROUGH SOIL STILL NOT DONE (WILL BE DELAYED FOR FORSEEABLE FUTURE) |
|
08/16/2010 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* SEE 707.6 2006 UPC CLEAN OUTS TO OPEN IN THE DIRECTION OF FLOW SEE90S.3 2006 UPC HORIZONTAL VENTING BELOW FLOOD RM DONT FORGET UTILITIES OUTSIDE FOUNDATION TO HAVE TRACER |
|
08/12/2010 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* |