Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T10CM00802

Parcel: 12620001C


Addresses:

3400 E ZOO CT


Inspection Status: Approved

Inspection History: ELECTRIC - UNDERGROUND

Permit Number - T10CM00802

Inspection Description - ELECTRIC - UNDERGROUND

Inspection Status - Approved

Date Description Inspector Results Comments
10/18/2011 ELECTRIC - UNDERGROUND Approved IVRS - Inspection :*
09/30/2011 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
1) OK POWER STUB UP FOR 110V AND 240V RECEPTS AT ER D
2) OK U.G. FOR SITE LTG. & CONV. RECEPTS AND AUDIO/VISUAL
08/17/2011 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
1) CONTINUE 4" PVC FOR FIBER-TO ACROSS ROAD
08/08/2011 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
1) OK SES ROOM 106
2) NEED LETTER OF TORQUE
3) GAS, WATER, BLDG STEEL BONDING
4) OK FEEDERS, COMM, ACROSS ROADWAY TO LSS BLDG
07/07/2011 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
1) OK TEP SECONDARY ROAD CROSSING AND X-FORMER LOCATION
2) OK CMU CONDUITS COMPLETE AT ELEPHANT BARN
06/20/2011 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
1) OK GROUND GRID #8 SOLID FOR POOL AND WATER FEATURE PERIMETER
2) OK MASONRY ELECTRICAL ELECTRIC ROOM U.G.
3) OK U.G. AT KOPJE PLANTER
05/31/2011 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
1) OK CONTINUED MASONRY AT ELEPHANT BLDG AND PVC U.G. SLIDE GATE KOPJE PLANTER
05/23/2011 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
1) OK PVC BEYOND COPJE PLANTER TO STUB UP OK TO SLIDE GATE
2) CONDUIT AND BOXES IN MASONRY WALL AT ELEPHANT BARN
05/17/2011 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
1) OK CONTINUE POWER CONDUITS TO KOBJE PLANTER
05/13/2011 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
1) OK U.G. WEST OF ELEPHANT BARN
05/10/2011 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
1) OK POWER/SECURITY CONDUITS, #4 BARE GROUND AT SLIDE GATE AREA
05/05/2011 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
1) OK CONTINUE 4" FIBER CONDUITS TO VAULT AT ELEPHANT BARN, ALSO CONDUIT (PVC) FEEDERS, FIELD DEVICES, EXTEND 3-4" FOR TEP SECONDARYS NORTH OF ELEPHANT BARN AND ELECTRIC ROOM
04/20/2011 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
04/18/2011 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
04/12/2011 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
THE ELECTRICAL CONTR. HAS ADDRESSED THE QUESTION OF BONDING REQUIREMENTS FOR THE ELEPHANT POOL TO THE INSPECTOR DAN SANTA CRUZ, SINCE THIS WAS NOT SHOWN OR COVERED ON THE PLANS, THE INSPECTOR ASKED THE ELECTRICAL FOREMAN TO RFI THE ENGINEER OF RECORD FOR DIRECTION OF GROUNDING OR BONDING REQUIREMENTS FOR POOL IN QUESTION. THE RESPONCE FROM THE DESIGNER WAS "ASK THE INSPECTOR". I (DAN SC) DISCUSSED THIS WITH RAAY MAJUTA & LEE RAY HANLEY COT AND IT WAS CONCLUDED TO ASK THE ELECTRICAL CONTR. TO MEET THE REQUIREMTNS ON ART 680.26 OF THE 2005 NEC FOR GROUNDING AND OR BONDING.
04/04/2011 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*