Permit: T10CM00802

Parcel: 12620001C


Addresses:

3400 E ZOO CT


Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Permit Number - T10CM00802

Inspection Description - REINFORCED MASONRY PRE-GROUT

Inspection Status - Approved

Date Description Inspector Results Comments
09/29/2011 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
09/26/2011 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
1) CANCELLED PER CONTRACTOR
07/29/2011 REINFORCED MASONRY PRE-GROUT Partial Approval OK TO GROUT AREAS APPROVED BY PHIL HAYWARD (SPECIAL INSPECTOR)
07/27/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) 1ST LIFT AT COPJ1 RETAINING WALL
07/21/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) CMU AT RHINO EXIBIT OK
07/11/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) ELEPHANT BARN COMPLETE EXCEPT WING WALLS
07/07/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) 8' TO 12'; NORHT WING WALL TOP OUT AND WEST WING WALL 1ST LIFT
2)
07/06/2011 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
1) NOT READY PER CONTRACTOR
07/01/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) CENTER PORTION LSS WALL 4' TO 8'
2) ELEPHANT BARN INTERIOR WALLS TOP OUT-NEXT CENTER 4' TO 8'
06/30/2011 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
06/24/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) 1ST LIFT NORTHWEST WING WALL
06/23/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) ELEPHJANT BARN SW EXTERIOR WALL TOPOUT
2) REMAINING DEEPER ILSE WALL 4' TO 8'
3) FIRST LIFT NW WALL E OF DOOR
4) LEFT S STATION RETANING WALL TOPOUT
06/21/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) LIFT STATION RETAINING WALL 1ST LIFT
06/20/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) TRAINING WALL TOP OUR, FOOD SERVICE 12 TO 14 TOP OUT AND WOMEN'S & MEN'S RESTROOMS 8 TO 12
06/15/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) WEST SIDE OF HALLWAY 8' TO 12'
2) NORTH WEST CORNER OF RESTROOM STORAGE 8' TO 12' 3RD LIFT
3) EAST WALL OF STORAGE TOP OUT
4) TRAINING WALL 8' TO 10'
06/13/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) WEST WALL OFF RESTROOM/STORAGE 2ND LIFT
2) 1ST LIFT BETWEEN NORTH DOORS
06/10/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) TRAINING WALL 2ND LIFT
2) 110, 111 & 112 EAST WALL 1ST LIFT NORTH WALL 110 1ST LEFT
3) EAST WALL ROOM 105 TOP
4) WEST WALL ROOM 108 2ND LIFT
06/08/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) ROOM 112 TOP OUT EAST AND SOUTH WALL, ROOM 111 EAST WALL TOP OUT, ROOM 108 EAST WALL 2ND LIFT, NORTH WALL ROOM 113 TOP OUT, TRAINING WALL 4 TO 8 EAST SIDE AND 0 TO 4 WEST SIDE
06/07/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) SOUTH WEST TOP OUT ROOM 113, 114, 115 AND 116
06/06/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :* 1) S&W WALLS OF 113, 114, 115, 116, 3RD LIFT
2) RM 111, 112 S&E WALLS TO 8'
06/02/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) CTS MECH ROOM WALL 1ST LIFT
06/01/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) SEPERATION WAL AT TRAINER ROOM 1ST LIFT
2) SOUTH WEST WALL 8" EXT. WALL 4 TO 8 44' FROM CORNER
3) WEST VAULT WALL TOP OUT
05/31/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) ELEPHANT BARN 12" BLOCK TOP OUT
05/26/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) MOAT RETAINING WALL (FOOTINGS) AS PER SKETCH #5/26/11 OK TO POUR FOOTINGS
05/24/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) EAST OF VAULT WALL 2ND LIFT
2) SOUTH WEST CORNER OF ELEPHANT BARN 12' TO 16'
05/20/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) WALL BETWEEN BLDG 1 AND COMMUNITY ROOM TO 12', EXCEPT LENTIL
2) SITE WALL WEST OF VAULT 1ST LIFT
05/19/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) VAULT SOUTH EAST SIDE SITE WALL TO 4' EXCEPT ROOM 101 & 102
2) CMU WALL 4 TO 8"
05/17/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) 12" 1ST LIFT OF STEM, SOUTH WEST CORNER 8' TO 12' SLIDING GATE STAIRWELL TOP OUT
05/13/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) ELEPHANT BORN 50' SOUTH AND WEST OF NORTHEAST CORNER TOP OUT
2) EAST WALL OF KEEPER ROOM 4 TO 8
3) CMU SLIDE GATE TO 8'
05/12/2011 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
1) NOT READY PER CONTRACTOR
05/11/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) BEDROOM #2 EAST WALL AT 20'-24' (TOP OUT); EAST AND NORTH WALLS AT 20'-24' (TOP OUT) COUMMUNITY ROOM OK TO GROUT
05/09/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) 12" & 8" CMU SITE RETAINING WALL FROM 0' TO 4' AT MANUAL SIDE GATE REBAR OK-SPECIAL INSPECTED CONFORMATECH
05/06/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) BEDROOM 3 DOORS ABOVE LINTELS AT 20' SOUTH WALL AT 0'-4' (WEST END) OK TO GROUT PROGRESS AREA
05/04/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) EAST WALL, SOUTH AND NORTH WALLS 16' TO 21' AND 12 TO 16 SHEET IN OFFICE
2) BAR TO BE ADDED AT BEAM POCKET
3) SPECIAL INSPECTION TO VERIFY OR DON'T POUR
05/03/2011 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
05/02/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :* 50' N WALL 12' TO 16' EAST WALL 12' TO 16'; SO WALL 16' TO 20' BETWEEN OPENING
WEST WALL 4' TO 8'
04/27/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) EAST WALL ELEPHANT BARN EXCEPT FOR LINTELS TO 16'
2) PROVIDE RFI REQUIRING STIRRUPS AT LINTELS CLARIFICATION
04/26/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
04/25/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
04/21/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) COMMUNITY ROOM, BEDROOMS 1 & 2 SOUTH, EAST AND NORTH TO 12' 8"
04/20/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) EAST WALL ELEPHANT BARN TO SOUTH AND NORTH CONTROL JOINTS TO 12' 8"
04/18/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
04/14/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
04/13/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) 12" CMU WALLS AT ELEPHANT HOLDING AREA 2ND LIFT FROM 4' TO 8' AFFE-OF PARTIAL NORTH AND EAST WALL AND ALL OF WEST WALL OK
2) SPECIAL INSPECTION BY CONFORMATECH
04/11/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*CMU WALLS FROM 0 TO 4' AFFE AT ELEPHANT ENCLOSURE . BEDROOM #1 NORTH & WEST WALL 0' TO 4' AFFE, BEDROOM #2 SOUTH STEM WALL, COMMON STEM WALL BETWEEN BEDROOM #1 & COMMUNITY RM. AND COMMUNITY RM NORTH WALL 0' TO 4' AFFE SPECIAL BY CONFORMATECH
04/07/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) BEDROOM #1 NORTH AND WEST WALL, BEDROOM #2 EAST WALL OF 12" CMU STEM WALLS FROM TOP TO 24" OK HOLD BACK 3 FT FROM JAMES FOR STEEL CHANGE-OK CONFORMATECH
03/24/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) SOUTHWEST CORNER RETAINING WALL COMPLETE
03/11/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
03/09/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) SOUTH WEST CORNER 9' RETAINING WALL 1ST LIFT
03/04/2011 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) 140' 1ST LIFT S.W. CORNER RETAINING WALL
2) SPECIAL INSPECTED