Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T10BU01638

Parcel: 11943001A


Addresses:

1655 W AJO WY #001


Inspection Status: Approved

Inspection History: GRADING - FINAL

Permit Number - T10BU01638

Inspection Description - GRADING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
06/15/2011 GRADING - FINAL Approved Approved
06/01/2011 GRADING - FINAL Partial Approval All items complete except for the Landscaping, need a revised plan for the west and south LS outside of walls or install per plan.
05/11/2011 GRADING - FINAL Denied Complete the following prior to final
1) Provide as-builts/revised site plan showing all changes made to site. Have plan reviewed and approved by PDSD.
2) Install outlet structure per plan or revise
3) Install access ramp per approved plan or revise.
4) Spread GD over all exposed areas per plan.
5) Install all LS per approved plan.
6) Remove excess soil from slope north of outlet structure and slope to fit.
7) Remove all construction debris.