Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T10BU01569

Parcel: 12901018M


Addresses:

191 S PLUMER AV


Inspection Status: Approved

Inspection History: GRADING - FINAL

Permit Number - T10BU01569

Inspection Description - GRADING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
11/10/2011 GRADING - FINAL Approved
09/28/2011 GRADING - FINAL Denied Preliminary Punch list, not all items complete. Complete the following prior to final approval.
1) Install Rip Rap and dumped rock in planters and outfalls per the approved plans.
2) Depress all LS areas and water harvest areas 6"
3) Install all wheel stops and stripe parking lot per approved plan.
4) Install gate on dumpster enclouser.
5) Finish basins in front with rip rap slopes per plan.
6) Finish all L.S.
7) remove all const. debris from the site.
8) submit an as-built to 201 N Stone. for Eng. review.