Permit: T10BU01213

Parcel: 105110700


Addresses:

4320 N ORACLE RD


Inspection Status: Approved

Inspection History: ENGINEERING PRE-CONSTRUCTION

Permit Number - T10BU01213

Inspection Description - ENGINEERING PRE-CONSTRUCTION

Inspection Status - Approved

Date Description Inspector Results Comments
10/05/2010 ENGINEERING PRE-CONSTRUCTION Approved SEDIMENT CONTROLS HAVE BEEN INSTALLED
A STABILIZED CONSTRUCTION ENTRANCE HAS BEEN INSTALLED.
CONTRACTOR MUST ENSURE CONTROLS ARE MAINTAINED THROUGHOUT CONSTRUCTION.
CONTRACTOR MUST PERFORM PERIODIC SELF INSPECTIONS PER THE APPROVED SWPPP.
09/30/2010 ENGINEERING PRE-CONSTRUCTION Correction Required 1) A STABILIZED CONSTRUCTION ENTRANCE HA BEEN INSTALLED.
2) CONTRACTOR MAY NEED TO INSTALL TWO ENTRANCE/EXITS BEING USED ON SITE IN ORDER TO REDUCE TRACKING OF SOIL.
3) SWEEP UP TRACKED SOIL OFF OF EXISTING PARKING AREA
4) THE EXISTING RET/DET BASIN ALONG THE WEST PERIMETER HAS BEEN SILTED - IN AND WILL NEED TO BE RE-CONSTRUCTED PER PLAN.
5) PLACE SEDIMENT CONTROLS AT ALL CURB CUTS, WALL OPENINGS, AND DRAINAGE STRUCTURE OUTLETS.
6) PERFORM STORM WATER SELF INSPECTIONS PER YOUR PLAN AND DOCUMENT THEM.
7) INSTALL A CONCRETE/ MATERIALS WASH-OUT WHEN APPLICABLE
09/28/2010 ENGINEERING PRE-CONSTRUCTION Correction Required CONSTRUCTION SITE IS IN NON-COMPLIANCE WITH NPDES/AZPDES/ AND THE COT STORM WATER ODINANCE.

1) INSTALL AND MAINTAIN SEDIMENT CONTROLS REQUIRED BY YOUR STORM WATER PLAN.
2) CALL IN FOR AN ENGINEERING PRE-CONSTRUCTION MEETING PRIOR TO CONSTRUCTION.
3) CALL FOR INSPECTION FOR COMPLIANCE WHEN COMPLETED.