Permit: T09ME00546

Parcel: 127021910


Addresses:

5338 E 4TH ST

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
01/22/2010 MECHANICAL - FINAL Approved IVRS - Inspection :*
1) CORRECTIONS HAVE BEEN MADE
08/31/2009 MECHANICAL - FINAL Partial Approval IVRS - Inspection :*
1) PROVIDE INSULATION ON EXPOSED SHEET METAL DUCT IN FURNACE ROOM
2) PROVIDE PURPLE PRIMER ON ALL PVC FITTINGS PRIOR TO GLUE
3) PROVIDE A HOSE CLAMP ON PUMP
4) PROVIDE A GFI SERVICE RECEPTACLE WITHIN 25' OF CONDENSOR
5) SECURE COPPER DRAIN LINE AND ISOLATE FROM STEEL. SUPPORT EVERY 6' ON ROOF AND TERMINATE TO THE GROUND