Inspection Status: Correction Required
Inspection History: VIOL - MEANS OF EGRESS
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/30/2009 | VIOL - MEANS OF EGRESS | Correction Required | IFC 1008.1.9 Panic and fire exit hardware. Where panic and fire exit hardware is installed, it shall comply with the following: 1. The actuating portion of the releasing device shall extend at least one-half of the door leaf width. 2. The maximum unlatching force shall not exceed 15 pounds (67 N). Each door in a means of egress from a GroupAor E occupancy having an occupant load of 50 or more and any Group H occupancy shall not be provided with a latch or lock unless it is panic hardware or fire exit hardware. _____1. The northwest patio door shall have panic hardware installed on the door. _____2. The patio gate shall have panic hardware installed on the inside of the gate. _____3. The northeast security grill shall have panic hardware installed on the inside of the security grill. ****NOTE: Panic hardware shall be the only locking device on the door. |
|
| 12/30/2009 | VIOL - MEANS OF EGRESS | Correction Required | IFC 1008.1.2 Door swing. Egress doors shall be side-hinged swinging. Doors shall swing in the direction of egress travel where serving an occupant load of 50 or more persons or a Group H occupancy. _____1. The northeast security grill shall swing outward in the direction of egress travel. |
|
| 12/30/2009 | VIOL - MEANS OF EGRESS | Correction Required | 1008.1.8 Door operations. Except as specifically permitted by this section egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. _____1. Remove the double keyed lock from the southeast door and replace it with a thumb-turn lock. |