Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case: T09FR03466

Parcel: 124040760


Addresses:

1509 E 2ND ST

Inspection Status: Approved

Inspection History: VIOL - MEANS OF EGRESS

Date Description Inspector Results Comments
01/28/2010 VIOL - MEANS OF EGRESS Approved
11/04/2009 VIOL - MEANS OF EGRESS Violation 1028.1 General. The means of egress for buildings or portions
thereof shall be maintained in accordance with this section.
1028.2 Reliability. Required exit accesses, exits or exit discharges
shall be continuously maintained free from obstructions
or impediments to full instant use in the case of fire or
other emergency...
1028.3 Obstructions. A means of egress shall be free from
obstructions that would prevent its use..

____Remove all obstructions from the exit passageway/exit access on the east side of the building. This includes all the sand.
11/04/2009 VIOL - MEANS OF EGRESS Violation 1028.6 Emergency escape openings. Required emergency
escape openings shall be maintained in accordance with the
code in effect at the time of construction, and the following:
Required emergency escape and rescue openings shall be operational
from the inside of the room without the use of keys or
tools. Bars, grilles, grates or similar devices are allowed to be
placed over emergency escape and rescue openings provided
the minimum net clear opening size complies with the code that
was in effect at the time of construction and such devices shall
be releasable or removable from the inside without the use of a
key, tool or force greater than that which is required for normal
operation of the escape and rescue opening.

____All the windows in the bedrooms serve as an emergency escape. Each bedroom needs at least one operational window. Currently the windows are sealed, screwed or bolted shut.
11/04/2009 VIOL - MEANS OF EGRESS Violation 1008.1 Doors. Means of egress doors shall meet the requirements
of this section.
1008.1.8 Door operations. Except as specifically permitted
by this section egress doors shall be readily openable from
the egress side without the use of a key or special knowledge
or effort.
1008.1.8.4 Bolt locks. Manually operated flush bolts or
surface bolts are not permitted.
1008.2 Gates. Gates serving the means of egress system shall
comply with the requirements of this section. Gates used as a
component in a means of egress shall conform to the applicable
requirements for doors.

____Remove the slidebolts on the interior foyer doors. One door can have slidebolts but the other must have a thumbturn lock.
____Remove the exterior slide bolts from the security gates on the east side of the building. The inside of the gates must have thumbturn locks or panic hardware. They cannot have keyed locks or slidebolts. These gates serve the means of egress.