Case: T09DV04749

Parcel: 126100150


Addresses:

502 N BELVEDERE AV

Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
08/18/2009 INSP - INITIAL CODE ENFORCMENT Approved VIOLATIONS PRESENT
HCD INSPECTOR CONDUCTED ON SITE INITIAL INSPECTION REGARDING GAS LEAK (DETERMINED BY SW GAS) WATER HEATER & PIPING INSTALLED W/O/P & MISSING SOV. OCCUPANT HAS NOT HAD HOT WATER FOR OVER TWO WEEKS. REPORTED TO REALTY CO ON 7/31/09. INSPECTOR MADE CONTACT W/OCCUPANT. REVIEWED COMPLAINT, INSPECTOR WAS ALLOWED ENTRY INTO STRUCTURE, VIOLATIONS ARE AS FOLLOWS:
ELECTRICAL SYS. POSSIBLE W/O/P
(1) INSTALLATION OF 3 PRONG RECEPTACLES INTO 2 WIRE SYSTEM. TEST EQUIPMENT FOUND SEVERAL 3 PRONG RECEPTACLES THROUGH OUT STRUCTURE LACKING GROUNDS.
(2) 2 PRONG RECEPTACLE AT COUNTER NORTHSIDE NOT WORKING, EVIDENCE OF ARCHING IS PRESENT.
(3) REQUIRED RECEPTACLE COVER PLATE LACKING BY FRIG.
(4) ILLEGAL ADDITION OF ELECTRICAL CIRCUITS FOR GARBAGE DISPOSAL & HOT WATER CLOSET.
(5) INSTALLATION OF WALL AC UNIT NOT HARD WIRED, USING APPLIANCE CORD IN LIEW OF PERMINENT WIRING.
(6) EXTERIOR RECEPTACLE 2 PRONG LACKING WEATHER PROOF COVER & DUE TO ELECTRICAL HAS BEEN MODIFIED, GFIC RECEPTACLE WILL BE REQUIRED.
(7) SUB-PANEL HAS BEEN MODIFIED IN A HAZARDOUS MANNER, IMPROPER INSTALLATION OF 3 DIFFERENT BRAND BRAKERS HAVE BEEN INSTALLED IN SUB-PANEL.
PLUMBING SYSTEM
(1) WATER SUPPLY SYSTEM HAS BEEN MODIFIED, APEX TYPE PLASTIC PIPING SYSTEM INSTALLED TO BATH TUB & HOT WATER HEATER.
(2) NEWER TYPE HWH INSTALLED W/PAN, PLUMBING QUESTIONABLE, GALVANIZED HOSE BIB CONNECTED TO COPPER ABOVE TANK IS NOT AN APPROVED INSTALLATION. CHECK FOR PERMIT.
POSSIBLE W/O/P ADDITION OF FAMILY ROOM, AC UNIT. RESEARCH REQUIRED.
WEATHER PROOFING:
(1) LARGE GAP AT BOTTEM OF ENTRY DOOR
PICTURES TAKEN.