Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/18/2009 | INSP - INITIAL CODE ENFORCMENT | Approved | VIOLATIONS PRESENT HCD INSPECTOR CONDUCTED ON SITE INITIAL INSPECTION REGARDING GAS LEAK (DETERMINED BY SW GAS) WATER HEATER & PIPING INSTALLED W/O/P & MISSING SOV. OCCUPANT HAS NOT HAD HOT WATER FOR OVER TWO WEEKS. REPORTED TO REALTY CO ON 7/31/09. INSPECTOR MADE CONTACT W/OCCUPANT. REVIEWED COMPLAINT, INSPECTOR WAS ALLOWED ENTRY INTO STRUCTURE, VIOLATIONS ARE AS FOLLOWS: ELECTRICAL SYS. POSSIBLE W/O/P (1) INSTALLATION OF 3 PRONG RECEPTACLES INTO 2 WIRE SYSTEM. TEST EQUIPMENT FOUND SEVERAL 3 PRONG RECEPTACLES THROUGH OUT STRUCTURE LACKING GROUNDS. (2) 2 PRONG RECEPTACLE AT COUNTER NORTHSIDE NOT WORKING, EVIDENCE OF ARCHING IS PRESENT. (3) REQUIRED RECEPTACLE COVER PLATE LACKING BY FRIG. (4) ILLEGAL ADDITION OF ELECTRICAL CIRCUITS FOR GARBAGE DISPOSAL & HOT WATER CLOSET. (5) INSTALLATION OF WALL AC UNIT NOT HARD WIRED, USING APPLIANCE CORD IN LIEW OF PERMINENT WIRING. (6) EXTERIOR RECEPTACLE 2 PRONG LACKING WEATHER PROOF COVER & DUE TO ELECTRICAL HAS BEEN MODIFIED, GFIC RECEPTACLE WILL BE REQUIRED. (7) SUB-PANEL HAS BEEN MODIFIED IN A HAZARDOUS MANNER, IMPROPER INSTALLATION OF 3 DIFFERENT BRAND BRAKERS HAVE BEEN INSTALLED IN SUB-PANEL. PLUMBING SYSTEM (1) WATER SUPPLY SYSTEM HAS BEEN MODIFIED, APEX TYPE PLASTIC PIPING SYSTEM INSTALLED TO BATH TUB & HOT WATER HEATER. (2) NEWER TYPE HWH INSTALLED W/PAN, PLUMBING QUESTIONABLE, GALVANIZED HOSE BIB CONNECTED TO COPPER ABOVE TANK IS NOT AN APPROVED INSTALLATION. CHECK FOR PERMIT. POSSIBLE W/O/P ADDITION OF FAMILY ROOM, AC UNIT. RESEARCH REQUIRED. WEATHER PROOFING: (1) LARGE GAP AT BOTTEM OF ENTRY DOOR PICTURES TAKEN. |