Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

08/14/2009

Applicant:

DAVIDSON DANIEL P & JOYCE BEAUDRY CP/RS

Description:

GAS LEAK (SW GAS DETERMINED), WATER HEATER AND WATER PIPING INSTALLED WITHOUT PERMITS AND MISSING SOV. OCCUPANT HAS NOT HAD HOT WATER FOR OVER 2 WEEKS. REPORTED TO REALTY CO ON 7-31-09. NOTE: INSPECTOR PLEASE CALL AT LEAST AN HOUR PRIOR TO GOING OUT.

Outstanding Inspections

Case Number: T09DV04749
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 6
End Date Description Inspector Results Comments
08/18/2009 NPO(PL)-GAS SUPPLY/CONNECT HLOPEZ Item closed
10/05/2009 NPO(EL)-MAIN/PANEL/SUB/DISCONT HLOPEZ Item closed
10/05/2009 NPO(EL)-WIRING/SWITCH/OUTLT/FX HLOPEZ Item closed
10/05/2009 NPO(PL)-PLUMBING SYSTEM & FX HLOPEZ Item closed
10/05/2009 NPO(PL)-WATER HEATERS HLOPEZ Item closed
10/05/2009 NPO - WORK WITHOUT PERMIT HLOPEZ Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T09DV04749
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
08/18/2009 INSP - INITIAL CODE ENFORCMENT HLOPEZ Approved VIOLATIONS PRESENT HCD INSPECTOR CONDUCTED ON SITE INITIAL INSPECTION REGARDING GAS LEAK (DETERMINED BY SW GAS) WATER HEATER & PIPING INSTALLED W/O/P & MISSING SOV. OCCUPANT HAS NOT HAD HOT WATER FOR OVER TWO WEEKS. REPORTED TO REALTY CO ON 7/31/09. INSPECTOR MADE CONTACT W/OCCUPANT. REVIEWED COMPLAINT, INSPECTOR WAS ALLOWED ENTRY INTO STRUCTURE, VIOLATIONS ARE AS FOLLOWS: ELECTRICAL SYS. POSSIBLE W/O/P (1) INSTALLATION OF 3 PRONG RECEPTACLES INTO 2 WIRE SYSTEM. TEST EQUIPMENT FOUND SEVERAL 3 PRONG RECEPTACLES THROUGH OUT STRUCTURE LACKING GROUNDS. (2) 2 PRONG RECEPTACLE AT COUNTER NORTHSIDE NOT WORKING, EVIDENCE OF ARCHING IS PRESENT. (3) REQUIRED RECEPTACLE COVER PLATE LACKING BY FRIG. (4) ILLEGAL ADDITION OF ELECTRICAL CIRCUITS FOR GARBAGE DISPOSAL & HOT WATER CLOSET. (5) INSTALLATION OF WALL AC UNIT NOT HARD WIRED, USING APPLIANCE CORD IN LIEW OF PERMINENT WIRING. (6) EXTERIOR RECEPTACLE 2 PRONG LACKING WEATHER PROOF COVER & DUE TO ELECTRICAL HAS BEEN MODIFIED, GFIC RECEPTACLE WILL BE REQUIRED. (7) SUB-PANEL HAS BEEN MODIFIED IN A HAZARDOUS MANNER, IMPROPER INSTALLATION OF 3 DIFFERENT BRAND BRAKERS HAVE BEEN INSTALLED IN SUB-PANEL. PLUMBING SYSTEM (1) WATER SUPPLY SYSTEM HAS BEEN MODIFIED, APEX TYPE PLASTIC PIPING SYSTEM INSTALLED TO BATH TUB & HOT WATER HEATER. (2) NEWER TYPE HWH INSTALLED W/PAN, PLUMBING QUESTIONABLE, GALVANIZED HOSE BIB CONNECTED TO COPPER ABOVE TANK IS NOT AN APPROVED INSTALLATION. CHECK FOR PERMIT. POSSIBLE W/O/P ADDITION OF FAMILY ROOM, AC UNIT. RESEARCH REQUIRED. WEATHER PROOFING: (1) LARGE GAP AT BOTTEM OF ENTRY DOOR PICTURES TAKEN.
10/05/2009 INSP - FOLLOW UP CODE ENFORCE HLOPEZ Approved VIOLATION ABATED/COMPLAINCE HCD INSPECTOR CONDUCTED COMPLIANCE INSPECTION REGARDING PLUMBING & ELECTRICAL REPAIRS TO BE COMPLETED UNDER PERMITS. MADE CONTACT W/TENANT, STATED ALL REPAIRS HAVE BEEN COMPLETED ALONG WITH FINAL INSPECTION. TENANT DID NOT HAVE COPIES, INSPECTOR TO RESEARCH COT PP RECORDS PIROR TO CLOSING. COT PP RESEARCHED, ELECTRICAL 7 PLUMBING HAVE BEEN COMPLETED. CLOSE CASE. T09EL02095 FINALED 9/23/09 PLUMBING T09PL01367 FINALED 8/17/09

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T09DV04749
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date Name
09/15/2009 CONTACTED BY PHONE
09/01/2009 CONTACTED BY MAILING
09/01/2009 NOTICE OF VIOLATION ISSUED
10/07/2009 VIOLATION CLOSED
08/25/2009 RESEARCH

Documents

File Name Document Type  
None DOCUMENTS VIEW
T09DV04749.PDF DOCUMENTS VIEW
None IMAGES VIEW