Inspection History Details
Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
Permit Number - T09CM02434
Inspection Description - EXCAVATION/LAYOUT REBAR & ZON
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/09/2010 | EXCAVATION/LAYOUT REBAR & ZON | Approved | IVRS - Inspection :* | |
04/30/2010 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | Masonry 10' - 14' @ col repairs. | |
04/30/2010 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | MASONRY FILL AT COLS LOBBY LEVEL OK | |
04/26/2010 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1) MASONRY COLUMN RFI #119 |
|
04/20/2010 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1) GALLERIA AREA SLAB OR GRADE AND SLAB ON DECK |
|
04/19/2010 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* | |
04/14/2010 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1) SLAB OK AT CONCOURSE LEVEL |
|
04/13/2010 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* | |
04/06/2010 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 2 C------- SOUTH OF ESCALATORS, STOP AT ESCALATOR SLAB ON ELEVATOR P.T. |
|
03/30/2010 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1) STEM AT ELEVATOR AND STEM ON EAST AND SOUTH ESCALATOR |
|
03/29/2010 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* 1) INCOMPLETE |
|
03/26/2010 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* | |
03/25/2010 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1) STEM AT ELEVATOR |
|
03/19/2010 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | SHOTCRETE WALL @ ESCALATOR NEARLY DONE. OK TO PROCEED WITH SPECIAL INSP APPROVAL. | |
03/17/2010 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1) ELEVATOR PIT AND ESCALATOR PIT OK |
|
03/08/2010 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | 1) HELICAL PIER CAGE PER DETAIL S5.02/15, G.L. 18.2E A-E/C.4 | |
02/02/2010 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | 1) ANCHORS OK TO OLAD AND COVER LINE 18.2 2) PLEASE PROVIDE SPECIAL INSPECTION REPORTS AND RECALL WHEN REBAR IN FOR FIX ON LINE ? AT Ee |
|
01/21/2010 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | CURB FOOTERS GL C.4-107 AS PER RFI #082 |
|
12/04/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | 4 EACH LIGHT POLE BASES N1/2 OF PK LOT | |
11/30/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | CAISSON CAGES OK FOR LIGHT POLE BASES | |
11/25/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | SPREAD FOOTINGS AT C.4/107 AND E2/107,103,102,101 OK TO PLACE WHEN SPECIAL INSPECTOR CONFIRMS. | |
11/24/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | 1) EE2/106,105,104 SPREAD FOOTINGS OK 2) C.4/106 SPREAD FOOTING OK 3) PIER CAP AT C.4/104 OK |
|
11/23/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | 1) GL C4-103.5 HOLE AND CAGE OK 2) GL 105-C.4 F-3 FOOTERS |
|
11/20/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | 1) GL A.E/109-108.5 | |
11/19/2009 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | INCOMPLETE | |
11/18/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | COLUMN FOOTER GL C4-104 | |
11/17/2009 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | INFO ONLY |