Permit: T09CM02265

Parcel: 134240330


Addresses:

6322 E FORDHAM DR

Inspection Status: Partial Approval

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
09/14/2009 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
1) SUPPORT HORIZONTAL PVC EVERY 4'
2) USE PURPLE PRIMER PRIOR TO GLUING FITTINGS
3) PAINT EXPOSED PVC WITH LATEX PAINT
4) ZIP TIES NOT APPROVED FOR HANGERS
5) INSULATE SHEET METAL DUCT FITTINGS IN ATTIC WITH R8 AND PROVIDE R8 FLEX DUCTS
6) SECURE ELECTRIC DISCONNECT ON ROOF
7) SECURE GAS PIPE IN ATTIC
09/04/2009 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*