Permit: T09CM02186

Parcel: 13101071E


Addresses:

2222 S CRAYCROFT RD

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Date Description Inspector Results Comments
09/08/2010 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
1) 2 NORTH EXTERIOR CMU COLUMNS FROM 12' TO 16' TOP OUT OK
09/07/2010 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) 2 CANOPY COLUMNS AT 12'-15' 4" OK TO GROUT-DETAIL #216, PAGE S2.1
09/02/2010 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) 2 CMU NORTH ENTRY COLUMNS FROM 8'-0" TO 12'-0" OK
09/01/2010 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) 2 FRONT ENTRY CMU COLUMNS FROM 4'-0" TO 8'-0" OK
2) 5 INTERIOR COLUMN FOOTINGS 3' X 3' OK
08/30/2010 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) FRONT PORCH FOOTINGS AND SLAB; 2 COLUMNS AT 0"-48" OK TO GROUT POUR AND PROGRESS AREA
08/19/2010 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) 2 CANOPY FOOTINGS AT NORTH ENTRY
08/18/2010 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
NOT READY CONTRACTOR CANCELLED
08/12/2010 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) EAST PATIO; NOTE #1, PAGE S.1.1; DETAIL #105, PAGE S.3.1 OK TO POUR PROGRESS AREA
08/10/2010 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) 4 PATIO CMU COLUMNS TO 8' TOP OUT OK
08/03/2010 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
07/30/2010 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) 4 COLUMNS EAST SIDE OF BLDG 1ST LIFT OK PRE-GROUT
07/29/2010 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
1) CONTRACTOR CANCELLED
07/23/2010 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) 3 COLUMN FOOTINGS 2-F40 AND 1-F30 AT S/E SIDE OF EMPLOYEE PATIO AREA-OK
2) SPECIAL INSPECTED BY WESTERN TECH
06/02/2010 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) SITE WALL REINFORCEMENT STEEL FOR FOOTING AT SOUTH EAST CORNER OF NEW ADDITION TO DRIVE WAY
05/26/2010 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) WEST & SOUTH SITE WALL FOOTINGS OK
03/05/2010 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
PERIMETER FOOTINGS FOR NEW METAL STORAGE BLDG - OK
SPECIAL INSPECTION BY WESTERN TECH
03/03/2010 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*