Permit: T09CM01653

Parcel: 140430130

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Permit Number - T09CM01653

Inspection Description - ELECTRIC - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
12/16/2010 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
11/05/2010 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) OK WALLS ROOM 425
10/29/2010 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
10/26/2010 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) OK WALL ROOM 400,424,426-428 AND 502
2) PANEL ON B-5 AND A-5
10/13/2010 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
07/27/2010 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) OK MAKE UP "LB-2" AND "LD-2"
07/21/2010 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) OK WALLS ROOM 510-512
07/19/2010 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. PROTECT PVC AT BASE PLATE WITH APPROVED NAIL STRAPS
2. CORRECTLY IDENTIFY FIRE ALARM BOXES PER 760.10

OK 510, 511 AFTER CORRECTIONS
OK COLUMNS "LB-2", "LB-3"
07/12/2010 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
06/09/2010 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
06/07/2010 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
05/17/2010 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) PROTECT PVC CONDIUTS AT BASE PLATE
OK WALLS ROOMS 305, 304, 302, SOUTH 1/3 308
03/26/2010 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) OK ABOVE CEILING
2) ROOMS 221,223 & 224 EXCEPT AS NOTED
3) FINISH VDV CABLING
4) FINISH POWER POLES
5) WAITING ON ANSWER PER ENVIRO AIR-NOTE NEW FOUND SMALL MOTOR ABOVE CEILING
03/17/2010 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) IS OLD EXISTING VDV CABLING AND WIRING METHODS RATED FOR RETURN AIR ENVIORMENTAL SPACE ?
2) FINISH POWER POLES AND VDV CABLING
3) OK ABOVE CEILING, EXCEPT AS NOTED
4) ROOM 301 NORTH WALL TO COLUMN #4
5) OK PANEL A-5 CONDUITS IN WALL AND MAKE UP
03/11/2010 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) OK ROOM 224 WALLS
2) OK PANEL J-4 MAKE UP
03/09/2010 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
03/02/2010 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
03/01/2010 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) IDENTIFY PANEL FOR CONDUCTOR PER 210.5C
2) FINISH 114 ABOVE CEILING
3) OK EAST WALL ROOM 223
02/16/2010 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
12/22/2009 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) OK MAKE UP LH3 AND LH3A
12/17/2009 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
12/16/2009 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) OK PANEL L/C-5 &5A
2) OK WALL 215-217
12/14/2009 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK WALLS 209-214
OK ABOVE CEILING 203 EXCEPT POWER ROLE & VDR
OK LIGHTS 300 ABOVE CEILING
12/07/2009 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*.
1) OK CONDUIT ON RACKS 208
2) OK WALLS 218 & 221
12/02/2009 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
12/01/2009 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
11/25/2009 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
11/23/2009 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) OK 3-T STAT BOX AND CONDUIT DISMISSING WALL 208
11/09/2009 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) NO MORE THAN 360 DEGREE IN CONDUIT RUNS
2) FILL UNUSED OPENINGS IN BOXES
3) ROOM 113, 113A,113B,113C AND 113D OK NEXT INSPECTION
10/28/2009 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) OK TO ENERGIZE PANELS L/J-3.5A, L/J-3.5 AND H/J-3.5
10/26/2009 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
10/19/2009 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) OK TO ENERGIZE PANELS H/K-0.6, H/J.5-2.5, L/J.5-2.5
2) OK FEEDER AND TAPS TO DISCONNECTS FOR VFD FOR AHU-1
10/05/2009 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) FINISH VDV TO CABLE TRAY PER 392
2) OK CONDUIT AND RACKS ROOM 101A
3) ONLY ONE CONDUCTOR PER LUG TERMINATION
4) OK TO ENERGIZE L2,L2A,L3 AND L3A-SUBJECT TO CONTRACTOR MAINTAINING LOCK OUT/TAG OUT
09/22/2009 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) OK WALL WEST OF COLUMN J
09/18/2009 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) LOOSE FITTINGS
2) PROTECT CONDUIT END FOR VDV CABLING (MECHANICAL WIRE)
3) OK TO ONE SIDE AT MECHANICAL AREAS
4) OK WALL REST WEST OF 'J'
5) 725.5 + 24, 800.3 + 24, 770.3 + 24 AND 300.11 WILL APPLY