Inspection Status: Denied
Inspection History: ELECTRIC - FINAL
Permit Number - T09CM01241
Inspection Description - ELECTRIC - FINAL
Inspection Status - Denied
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/23/2009 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) LABEL ALL CIRCUITS 2) ONLY ONE WIRE PER BREAKER 3) 30 AMP SINGLE POLE BREAKER TO BE A 20 FOR ONE CIRCUIT AND 15 AMP FOR SECOND CIRCUIT, 30 AMP WONT PROTECT THOSE SMALLER WIRES 4) WHAT BRAND SUB PANEL IS THIS ? YOU HAVE MANY DIFFERENT BREAKERS. YOU ARE REQUIRED TO USE BREAKERS OF THE SAME BRAND AT THE PANEL 5) CLEAN UP WIRE CONNECTION AT 100 AMP BREAKER 6) SHORT PIECE OF ROMEX CUT OFF, BELOW SUB PANEL UNDER THE HOME 7) NEED SCREWS TO CLOSE PANEL COVER 8) MY OPINION YOU NEED A NEW PANEL 9) NOTE: DO NOT CONNECT NATURAL GAS TO HOUSE LINE UNTIL YOU CHECK WITH GAS COMPANY |
|
11/19/2009 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) NO ANSWER AT DOOR |
|
11/17/2009 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* |