Permit: T09CM00849

Parcel: 117050020


Addresses:

400 N 2ND AV


Inspection Status: Approved

Inspection History: SITE - SEWER

Permit Number - T09CM00849

Inspection Description - SITE - SEWER

Inspection Status - Approved

Date Description Inspector Results Comments
12/30/2010 SITE - SEWER Approved IVRS - Inspection :*
09/16/2010 SITE - SEWER Partial Approval IVRS - Inspection :*
09/14/2010 SITE - SEWER Not ready for Inspection IVRS - Inspection :*
1) UNABLE TO LOCATE SITE UTILITY PLAN (APPROVED)
08/30/2010 SITE - SEWER Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE C.I. PIPING ON C.I. PIPING SYSTEM, WITH PIPING IN CORRECT ALLIGNMENT, WITH APPROVED TRANSITION OR LISTING FOR CONNECTION FROM C.I. TO SDR 35
03/19/2010 SITE - SEWER Partial Approval IVRS - Inspection :*
1) INSTALL TRACER WIRE FROM MANHOLE TO 2 WAY CLEANOUT
2) REMOVE BROKEN MASONRY FROM CONNECTION AT TOILET ROOM B-107
3) OK TO COVER CONNECTION OUTSIDE LOCKER ROOMS
03/18/2010 SITE - SEWER Partial Approval IVRS - Inspection :*
1) 4" SDR 35 EXTENDED FROM EXISTING TO POC WITH BLDG DRAIN OUTSIDE LOCKER ROOMS OK
2) BLDG DRAIN NOT CONNECTED TO BLDG SEWER
3) 4" SDR 35 EXTENDED FROM POC WITH EXISTING SEWER TO JUST OUTSIDE TOILET ROOM B107 BUT NOT CONNECTED TO BLDG DRAIN
4) WATER TEST OK
5) OK TO BACKFILL THESE TWO AREAS
09/02/2009 SITE - SEWER Partial Approval 1) 4 PSI AIR TEST OK
08/31/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
1) 4" SDR 35 CONTINUES NORTH THRU CLEANOUT #2 TO CLEANOUT #1 WHICH IS 2 WAY, BEDDING LAYING, GRADE, SHADE AND TRACER
2) WILL AIR TEST AT LATER DATE
08/28/2009 SITE - SEWER Partial Approval IVRS - Inspection :*
1) 4" FROM EXISTING SOUTH EAST 8" THRU TO CLEANOUT #3 PER RED PAGES CLEANOUT 1.3 SERVING AS RED LINE DRAWING BECAUSE OF SITE CONDITIONS. THIS PLAN NEEDS PLAN CHECK STAMP
2) PROVIDE CORRECT TRANSITION COUPLINGS FOR SDR TO DUCTILE. WILL AIR TEST AT LATER DATE
3) VERIFICATION OF GRADE DONE ON SITE