Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T09CM00849

Parcel: 117050020


Addresses:

400 N 2ND AV


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T09CM00849

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
02/05/2010 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
11/06/2009 PLUMBING - ROUGH, SOIL Partial Approval 1) PARTIAL RE-ROUGH AT FOOTING LOCATIONS OK TO COVER
10/14/2009 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
1) OK TO COVER UNDERGROUND
10/13/2009 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
1) WET VENTED SECTIONS TO BE ONE PIPE SIZE LARGER THAN THE MINIMUM WASTE SIZE FOR THE UPPER FIXTURE
2) CHECK FOR BACK PITCHED SECTIONS
10/02/2009 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
1) 2 1/2" CW AND 1" HW UNDERGROUND FROM MECHANICAL ROOM TO THE THIRD TURN OK TO COVER
2) SINGLE BATHS B102 AND B107 OK TO COVER UNDERGROUND
10/01/2009 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*