Permit: T09CM00795

Parcel: 12620001C


Addresses:

900 S RANDOLPH WY

Inspection Status: Not ready for Inspection

Inspection History: STEM WALL/RETAINING WALL

Date Description Inspector Results Comments
08/05/2010 STEM WALL/RETAINING WALL Not ready for Inspection IVRS - Inspection :*
03/25/2010 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
1) WALL #3 0' TO 37' FROM SOUTH END OF WALL 0' TO 32" A TO F
2) SPECIAL INSPECTION BY WESTERN TECH
03/23/2010 STEM WALL/RETAINING WALL Not ready for Inspection IVRS - Inspection :*
1) CONTRACTOR CANCELLED
03/22/2010 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
15' & 10' WALLS #3 SECTIONS @ MAX 5' RETAINING WALL SECTIONS
03/17/2010 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
1) WALL #3 10' TO 40' SOUTH OF NORTH END OF WALL 0 TO 4' A.T.O.F.
2) WALL #4 0' TO 7' EAST OF WEST END OF WALL 0' TO 2'-5" A.T.O.F. COMPLETES WALL #4
3) SPECIAL INSPECTION BY WESTERN TECH
03/15/2010 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
1) APPROX 30 L.F. OF WALL #4 AT 0"-30" (MIDDLE SECTION) ; WALL #3 APPROX 30 L.F. OF RETAINING WALL-0"-47" (MIDDLE SECTION); WALL #1 APPROX 10 L.F. AT 54" WALL COMPLETE OK TO POUR PROGRESS AREAS
03/10/2010 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
1) WALL #1-31' TO 61' EAST OF WEST END 0' TO 4'-6" A.T.O.F.
2) WALL #4-0' TO 30' NORTH OF SOUTH END FROM 0' TO 2'-6" A.T.O.F.
3) SPECIAL INSPECTION BY WESTERN TECH
03/04/2010 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
1) WALL #1 FROM 12' TO 21' EAST OF WEST END
2) 0' TO 3'-6" A TO F & 61' TO 91' OF WEST END FROM 0' TO 4'-6" A TO F
3) WALL #2 FROM 0' TO 23' WEST OF EAST END 0' TO 2'-6" A TO F
4) SPECIAL INSPECTED BY WESTERN TECH
03/02/2010 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
1) STEM WALL/RETAINING WALL AT 22ND ST AND RANDOLPH WAY-APPROX 40' AT 0"-54"; 12' AT 0-30" OK TO POUR PROGRESS AREA DETAIL #1, PAGE D-4
02/26/2010 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
1) RETAINING WALL ON 22ND ST-WEST OF BRIDGE APPROX 75' AT 0"-32" OK TO POUR REMAINING EAST PORTION
2) RETAINING WALL AT 22ND AND RANDOLPH WAY-APPROX 75' AT 0"-32"; 32:-54" OK TO POUR PROGRESS AREAS
02/25/2010 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
1) RETAINING WALL (APPROX 150 L.F.) AT 22ND ST AND RANDOLPH WAY 0"-32" AND 32"-54" OK TO POUR PROGRESS AREA
02/24/2010 STEM WALL/RETAINING WALL Partial Approval IVRS - Inspection :*
REINFORCEMENT STELL AT CONCRETE RETAINING WALL #1
NORTH 22ND STREET @ STA 34 +74 - 35+-4 & STA 35+46 - 35+36, SPECIAL INSPECTION BY WESTERN TECH.
02/09/2010 STEM WALL/RETAINING WALL Not ready for Inspection IVRS - Inspection :*