Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/11/2009 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* 1) CLOSET FLANGES OK, KEEP OPEN SEWER PIPING CAPPED OR PLUGGED DURING CONSTRUCTION FOR SAFETY 2) JANITOR SINK PIPING OK TO COVER |
|
| 08/10/2009 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) P-6 NOT UNDER TEST 2) MISSING FHA STRAP 3) CLOSET FLANGES NOT SECURED |
|
| 08/07/2009 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) PIPE INSULATION-OK 2) SECURE CLOSET FLANGES |
|
| 08/06/2009 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) PROVIDE WELDER CERTS 2) 60 + PSI TEST OK 3) USE LOW PSI TEST FOR REMAINDER 4) DWV AND WATER KIT AREA OK 5) RECALL FOR PIPE INSULATION |
|
| 07/17/2009 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) PIPE INSULATION IN WALL AT TRM'S AND OVERHEAD IN HALL-OK |
|
| 07/16/2009 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) DWV WITH TEST THRU ROOF AND DOMESTIC WATER WITH 100 PSI TEST IN TOILET ROOMS AND AT P-4 AND P-7 (ICE MAKER) FIXTURES OK TO INSULATE |