Permit: T09CM00692

Parcel: 13711429H


Addresses:

1715 W IRVINGTON RD

Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Date Description Inspector Results Comments
02/05/2010 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
10/30/2009 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
10/27/2009 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) DUMPSTER ENCLOSURE OK
10/15/2009 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) NW AND NE ARCHED CORNERS AND RETURNS TOP OUT
2) PATT/EVAN SPECIAL INSPECTED
10/14/2009 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) STORE FRONT ENTRY STEM
10/13/2009 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) 16'-4" LIFT EAST HALF
2) 16'-18' NORTH AND EAST WEST CORNERS, TOP OUT SOUTH AND 40' OF EAST AND WEST WALLS
10/08/2009 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) WEST WALL TO 16', SOUTH WALL TO 65' FROM SW CORNER TO 14'-8"
2) PATT AND EVANOFF SPECIAL INSPECTED
10/07/2009 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
10/06/2009 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) EXTERIOR WALLS TO 12' EXCEPT BETWEEN STEEL COLUMNS
2) PAT-EVANOFF SPECIAL INSPECTED
10/05/2009 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) SOUTH WALL OFF WEST CORNER 54'-8" TO 8'
2) N.E. AND N.W. CORNERS TO 1ST CONTROL JOINT TO 2'
3) PAT EVANOFF SPECIAL INSPECTED
10/02/2009 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) EAST WALL 8' AFF, NE WALL 18' 8' AFF NW CORNER 18' 8" AFF, W. WALL 28' OFF SW CORNER TO 12'
2) PATT AND EVANOFF SPECIAL INSPECTED
10/01/2009 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) SOUTH WALL 56' TO 8" HIGH FROM S.E. CORNER
2) WEST WALL 28' TO 8' HIGH FROM SOUTHWEST CORNER
3) PATT EVANOFF SPECIAL INSPECTED
09/30/2009 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) SOUTH WALL TO 4' ABOVE STAIR, EWOEL 4' ABOVE STAIR, WEST WALL FROM EAST CORRIDOR 18'-4" ABOVE STAIR
2) PATT EVENOFF SPECIAL INSPECTED
09/29/2009 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) WEST WALL FROM SOUTH CORNER 27'-4" 1ST LIFT
2) SOUTH WALL FROM WEST CORNER TO 34'