Permit: T08PL01244

Parcel: 133033000


Addresses:

9855 E SPEEDWAY BL

Inspection Status: Approved

Inspection History: PLUMBING - SEWER HCS CONNECT

Date Description Inspector Results Comments
12/24/2009 PLUMBING - SEWER HCS CONNECT Approved IVRS - Inspection :*
06/23/2009 PLUMBING - SEWER HCS CONNECT Not ready for Inspection IVRS - Inspection :*
YOU NEED A SITE PERMIT FOR YOUR DOMESTIC WATER AND A SITE UTILITY PLAN W/MECH. PLAN REVIEW

P0.0 PLAN REFERS TO CIVIL DRAWINGS FOR MORE INFORMATION. PROVIDE MATERIAL SPECS.
06/12/2009 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection :*
CONNECTIONS TO MAIN OK
PROVIDE PROPER SHADING, SUPPORT AND WIRE
06/11/2009 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection :*
SECURE 4" OFF PIPING
KEEP ROCKS OFF PIPING
KEEP DIRT OUT
06/10/2009 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection :*
CITY APPROVED PLAN ON SITE, CALL IN O3054 FOR APPROVAL

8" SDR35 INSTALLED FROM PUBLIC MANHOLE TO NEW MANHOLE #1 TO NEW MANHOLE #2 TO #3 TO #4,
#2 TO #5 AND #5 TO #6, WATER STOPS INSTALLED AT ALL MANHOLES, BACKFILLING IN ONGOING FROM #2 TO #5,
TRACER WIRE IS INSTALLED WITH WIRE NUT
BETWEEN #2 & #5, NO HCS LATERALS AT THIS TIME.

BEDDING, LAYING, TRACER, TESTING OF PIPING AND VACUUM TEST OF MANHOLES WITH VERIFICATION OF GRADE WITH THIRD PARTY INSPECTOR AT LATER DATE.