Permit: T08ME00096

Parcel: 125121340


Addresses:

3439 E HAWTHORNE ST

Inspection Status: Denied

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
03/14/2008 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
- CONNECT OVERFLOW SENSOR FROM CONDENSATE PUMP
- TIGHTEN ROMEX CONNECTOR ONTO POWER CORD TO FURNACE
- PLASTIC OVERFLOW SENSOR IS TOO CLOSE TO VENT CONNECTOR
- USE COPPER & RELOCATE SENSOR AWAY FROM VENT
- INSULATE ALL EXPOSED SHEETMETAL DUCT IN FURNACE CLOSET
- DO NOT USE TAPE TO SEAL VENT CONNECTOR
- VENT IS NOT REQUIRED TO BE SEALED
- SECURE THE COPPER WATER LINE FROM PUMP
- I'M THE FUTURE, USE PRIMER ON ALL PVC FITTINGS
- IDENTIFY CIRCUIT BREAKER
- PROVIDE A PERMIT FOR ELEC. SERVICE UPGRADE
- PROVIDE THE REQUIRED GFI SERVICE RECEPTACLE AT CONDENSOR
- DOUBLE WALL VENT NOT TERMINATED WITH AN APPROVED CAP AND IS INSTALLED UPSIDE DOWN