Case: T08FR04503

Parcel: 137031110


Addresses:

5244 S NOGALES HY

Inspection Status: Violation

Inspection History: VIOL - MEANS OF EGRESS

Date Description Inspector Results Comments
12/01/2008 VIOL - MEANS OF EGRESS Violation TFC 1011.2 - Illumination. Exit signs shall be internally or externally illuminated.
_____ Repair/replace exit signs
12/01/2008 VIOL - MEANS OF EGRESS Violation TFC 1006.1 - Illumination required. The means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied.
_____ Provide emergency lighting that is activated by loss of power to building.
12/01/2008 VIOL - MEANS OF EGRESS Violation TFC 1003.6 - Means of egress continuity. The path of egress travel along a means of egress shall not be interrupted by any building element other than a means of egress component as specified in this chapter. Obstructions shall not be placed in the required width of a means of egress except projections permitted by this chapter. The required capacity of a means of egress system shall not be diminished along the path of egress travel.
_____ Clear exit path, and maintain it this way.
12/01/2008 VIOL - MEANS OF EGRESS Violation 1008.1 Doors. Means of egress doors shall be readily distinguishable from the adjacent construction and finishes such that the doors are easily recognizable as doors
12/01/2008 VIOL - MEANS OF EGRESS Violation 1008.1.8.4 Bolt locks. Manually operated flush bolts or surface bolts are not permitted.