Inspection History Details
Inspection Status: Correction Required
Inspection History: VIOL - MEANS OF EGRESS
Case Number - T08FR02336
Inspection Description - VIOL - MEANS OF EGRESS
Inspection Status - Correction Required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/08/2008 | VIOL - MEANS OF EGRESS | Correction Required | TFC 1028.3 Obstructions. A means of egress shall be free from obstructions that would prevent its use. _____1.Remove the storage from obstructing the egress door located in the parts storage room. _____2.The east exterior door located in the machine shop shall not be obstructed by machinery. |
|
| 08/08/2008 | VIOL - MEANS OF EGRESS | Correction Required | TFC 1008.1.8 Door operations. Except as specifically permitted by this section egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. _____1.Remove the double-keyed lock from the east exterior door located in the machine shop. NOTE:Replace the double-keyed lock with a thumb-turn lock. _____2.Remove the double-keyed lock from the exterior door located in the southeast bay. NOTE:Replace the double-keyed lock with a thumb-turn lock. |