Case: T08FR02035

Parcel: 10707022A


Addresses:

926 W GRANT RD

Inspection Status: Correction Required

Inspection History: VIOL - MEANS OF EGRESS

Date Description Inspector Results Comments
07/17/2008 VIOL - MEANS OF EGRESS Correction Required 1008.1.8.5 Unlatching.
The unlatching of any door or leaf shall not require more than one operation.

_____ The front main entrance door secondary locking device shall be disabled or replaced to meet code standards. I.E. the lock shall release when twisted from the interior side.

1008.1.8.4 Bolt locks.
Manually operated flush bolts or surface bolts are not permitted.

_____ The slide bolt shall be removed and/or replaced with a approved locking device from the rear egress door. The door shall comply with code 1008.1.8.5.