Permit: T08EL01935

Parcel: 126130030


Addresses:

4633 E 12TH ST

Inspection Status: Denied

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
10/09/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) GROUND WIRE CUT OFF AND REMOVED AT SERVICE PANEL, INSTALL NEW GRD WIRE AND H20 BOND
2) NEED WORKING SMOKE DETECTORS IN EACH BEDROOM AND ONE IN HALLWAY
3) HOUSE WIRING IS AN UNGROUNDED SYSTEM USE ONLY 2 PRONG RECEPTS, UNLESS PROTECTED BY GFCI
4) GFCI PROTECTION REQUIRED FOR KIT RECEPTS, COUNTER TOP ONLY
5) SECURE PLASTIC CONDUIT DRYER
6) ALL A/C UNITS TO BE HARD WIRED, CORDS NOT APPROVED FOR EXTERIOR, ON PROTECTED USE
7) ROMEX EXPOSED EAST SIDE EXT. LIGHT