Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T08EL01589
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/24/2008 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* 1) OK KITCHEN GFI'S 2) SMOKE DETECTORS IN BEDROOM OK 3) SMOKE DETECTOR IN HALL WALL OK 4) CLOSET LIGHT IS ENCLOSED OK |
|
08/22/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. ALL KITCHEN COUNTER RECEPTACLES TO BE GFI PROTECTED 2. INSTALL SMOKE DETECTORS IN BEDROOMS PER INSTRUCTIONS 3. SMOKE DETECTOR IN HALL TO BE AC POWERED WITH BATTERY BACK UP 4. CLOTHES CLOSET LIGHT TO BE 100% ENCLOSED |