Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
Permit Number - T08EL00067
Inspection Description - ELECTRIC - RECONNECT
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/18/2008 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection :* | |
| 01/16/2008 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. KITCHEN COUNTER RECEPTACLES TO BE GFI PROTECTED 2. BATHROOM RECEPTACLES TO BE GFI PROTECTED THIS INCLUDES RECEPTACLE IN LIGHT FIXTURE 3. INSTALL SMOKE DETECTORS IN BEDROOMS & ONE OUTSIDE BEDROOMS PER MANUFACTURES INSTRUCTIONS 4. RECALL WHEN READY |