Case: T08DV00764

Parcel: 111031380


Addresses:

3241 E HALCYON PL

Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
02/01/2008 INSP - INITIAL CODE ENFORCMENT Approved HEAT PUMP INSTALLED ON ROOF WITHOUT PERMITS. WATER HEATER INSTALLED/RELOCATED WITHOUT PERMITS. 3 ADDITIONS TO MAIN STRUCTURE. CARPORT ENCLOSED, REAR ROOM ADDITION AND REAR WASHROOM ADDED WITHOUT PERMITS. REAR WASHROOM HAS ADDED WATER LINES.
EXPOSED CIRCUIT IN THE LIVING ROOM AREA EAST WALL NEAR HALLWAY. OPEN GROUND IN THE LIVING ROOM. REAR ROOM ADDITION, SOUTHEAST CORNER OUTLET SHOWS OPEN NUETRAL. CARPORT ADDITION OUTLETS SHOW OPEN GROUND. MAIN ELECTRICAL SERVICE PANEL HAS MISMATCHED BREAKERS AND LACKS PROPER LABELING. SERVICE PANEL DOOR DOES NOT SHUT PROPERLY. RETURN VENT IN THE LIVING ROOM LEAKS. BATHROOM DRAIN STOP AND WATER LINES LEAK. FAUCETS DO NOT WORK PROPERLY. KITHCHEN SINK LEAKS FROM SINK BASE AND LINES. WATER HEATER LACKS COLD WATER SHUT-OFF VALVE. WASHING MACHINE CONNECTED TO VENT PIPE IMPROPERLY ALLOWING SEWAGE GASES TO ENTER THE ROOM. KITCHEN LOWER CABINEST TO THE RIGHT OF THE SINK HAS HOLES IN THE WALL. FRONT DOOR AND REAR ROOM ADDITION DOOR LACK PROPER SEAL. DOES NOT PROVIDE ADEQUATE PROTECTION FROM THE ELEMENTS. RM