Case: T08DV00764
Case Details
Entered Date:
01/28/2008
Applicant:
CHAPMAN MICHELE & DONALD CP/RS
Description:
BATHROOM SINK LEAKS, FOUL ODOR NOW. ROACH INFESTATION AND POSSIBLE RWOP. NEW AC/HEATER UNIT INSTALLED ON ROOF. OCCUPANT NEEDS TO BE CONTACTED PRIOR TO INSPECTION 2 ALLOW ENTRY
Outstanding Inspections
Case Number: T08DV00764
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 7
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/01/2008 | NPO - INSECTS/PESTS | RMENDOZA | Item closed | |
| 04/29/2008 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | RMENDOZA | Item closed | |
| 04/29/2008 | NPO(PL)-PLUMBING SYSTEM & FX | RMENDOZA | Item closed | |
| 04/29/2008 | NPO(HC)-HEATING & VENTILATION | RMENDOZA | Item closed | |
| 04/29/2008 | NPO - EXT. BUILDING MAINTENANC | RMENDOZA | Item closed | |
| 04/29/2008 | NPO - INT. BUILDING MAINTENANC | RMENDOZA | Item closed | |
| 10/21/2009 | NPO - WORK WITHOUT PERMIT | RMENDOZA | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T08DV00764
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/01/2008 | INSP - INITIAL CODE ENFORCMENT | RMENDOZA | Approved | HEAT PUMP INSTALLED ON ROOF WITHOUT PERMITS. WATER HEATER INSTALLED/RELOCATED WITHOUT PERMITS. 3 ADDITIONS TO MAIN STRUCTURE. CARPORT ENCLOSED, REAR ROOM ADDITION AND REAR WASHROOM ADDED WITHOUT PERMITS. REAR WASHROOM HAS ADDED WATER LINES. EXPOSED CIRCUIT IN THE LIVING ROOM AREA EAST WALL NEAR HALLWAY. OPEN GROUND IN THE LIVING ROOM. REAR ROOM ADDITION, SOUTHEAST CORNER OUTLET SHOWS OPEN NUETRAL. CARPORT ADDITION OUTLETS SHOW OPEN GROUND. MAIN ELECTRICAL SERVICE PANEL HAS MISMATCHED BREAKERS AND LACKS PROPER LABELING. SERVICE PANEL DOOR DOES NOT SHUT PROPERLY. RETURN VENT IN THE LIVING ROOM LEAKS. BATHROOM DRAIN STOP AND WATER LINES LEAK. FAUCETS DO NOT WORK PROPERLY. KITHCHEN SINK LEAKS FROM SINK BASE AND LINES. WATER HEATER LACKS COLD WATER SHUT-OFF VALVE. WASHING MACHINE CONNECTED TO VENT PIPE IMPROPERLY ALLOWING SEWAGE GASES TO ENTER THE ROOM. KITCHEN LOWER CABINEST TO THE RIGHT OF THE SINK HAS HOLES IN THE WALL. FRONT DOOR AND REAR ROOM ADDITION DOOR LACK PROPER SEAL. DOES NOT PROVIDE ADEQUATE PROTECTION FROM THE ELEMENTS. RM |
| 07/01/2009 | INSP - FOLLOW UP CODE ENFORCE | RMENDOZA | Approved | UNIT REMAINS VACANT. NO UTILITIES. SECURED. PLACE IN OBSERVE. FOLLOW UP 90 DAYS. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T08DV00764
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 7
| Date | Name |
| 01/22/2009 | CONTACTED BY PHONE |
| 06/04/2008 | CONTACTED BY MAILING |
| 02/20/2008 | NOTICE OF VIOLATION ISSUED |
| 06/04/2008 | CITATION ISSUED |
| 10/26/2009 | VIOLATION CLOSED |
| 06/04/2008 | RESEARCH |
| 04/13/2009 | FORECLOSURE |