Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/11/2009 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 11/17/2009 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) THIS PANEL NOT LISTED FOR USE WITH SPLIT BREAKERS. SPLIT BREAKERS INSTALLED IN PANEL ARE FOR REPLACEMENT USE ONLY NOT FOR NEW INSTALLS 2) EXPOSE UNDERGROUND CABLING TO POLE, MINIMUM DEPTH TO BE PER NEC 300.5 3) EXPOSE PVC TO BE SCHEDULE 80, STRAP WITHIN 3' OF PANEL CONNECTION 4) CONNECT EQUIPMENT GROUND TO POLE 5) NEED TO VERIFY WATTAGE OF LAMP 6) HEIGHT OF POLE TO BE NO MORE THAN 12' PER PLANS |
|
| 11/09/2009 | ELECTRIC - FINAL | Denied | IVRS - Inspection : There is no plan or job inspection card on site.| 925* 1) POST ADDRESS ON HOUSE 2) HAVE APPROVED PLANS AND PERMITS ON SITE 3) ALL NEW WORK TO BE EXPOSED |