Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
Permit Number - T08CM03401
Inspection Description - REINFORCED MASONRY PRE-GROUT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/08/2010 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* | |
11/12/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) TOP OUT ON ARCHES |
|
11/05/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) TOP OUT SOUTHEAST CORNER, 22' ON NORTH COLUMNS |
|
11/02/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) TOP OUT NORTH WEST CORNER, 8' CENTER COLUMNS |
|
10/28/2009 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
10/26/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1ST LIFT ON COLUMNS NORTH SIDE |
|
10/21/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL 5-8/A 8/A-H.5 TOP OUT |
|
10/18/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) GL K/4-5.8 5.8/K-I, 5.8-7.3/I A/B-H.5, 6-7/A |
|
10/14/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) TOP OUT GL B-M/1, M/1-4, 12' LIFT GL B/1-1.7, 1.7/A-B |
|
10/13/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 2ND LIFT 2ND FLOOR WEST HALF |
|
10/09/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 1) 2ND FLOOR 1ST LIFT GL 4.1-8/I-J-K, 16' WEST WALL GL 1.4.1/M-A | |
10/06/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 2ND FLOOR WEST HALF 2ND LIFT |
|
10/01/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 2ND FLOOR WEST HALF 4' LIFT |
|
08/28/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 12'-14' NORTH AND EAST LINES |
|
08/27/2009 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* 1) MISSING REBAR |
|
08/26/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) POURED COLUMNS AT NORTH AND EAST SIDES |
|
08/20/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 15 POURED COLUMNS G.L 1-4.1/B-M |
|
07/23/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 11'-8" EAST WALL AND NORTH EAST WALL AND ELEVATOR SHAFT |
|
07/21/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) PERIMETER WALLS 8'-11"; ELEVATOR AT 0'-4"; PARTIAL NORTH WALL 0'-4"; OK TO GROUT PROGRESS AREAS SOUTH WALL (1/2) TO NW CORNER AT 8'-11" |
|
07/16/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 2ND LIFT |
|
07/08/2009 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 1ST LIFT WEST, SOUTH AND EAST |
|
07/06/2009 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* 1) CONTRACTOR CANCELLED |
|
07/02/2009 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* 1) INCOMPLETE |