Permit: T08CM01902

Parcel: 136261260

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T08CM01902

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
01/22/2009 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
07/30/2008 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
DWV THRU ROOF FOR STARBUCKS PER REDLINE ON SITE OK
WILL REQUIRE CITY APPROVED PLAN SHOWING DIRECT DRAINAGES WITH AIR ADMITTANCE VALVES AT BOTH SINKS.
WATER PIPING UNDERGROUND AND IN WALL AT NORTH
WALL OK

AFTER HRS. INSP. CHK#6806257315 - $150.00
07/29/2008 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
UNDERGROUND THRU VENT TO EXISTING VENT FOR HAND SINK AND FISH SINK IN SEAFOOD PREP OK
WATER THIS AREA OK
WRAP PIPES THRU CONCRETE AT FLOOR LEVEL PRIOR TO POUR BACK.

1. ON CWV AT STARBUCKS 2" FIXTURES REQUIRE 2" TAILPIECES WITH INCREASER AT P-TRAP
07/25/2008 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
4" CWV FROM EXISTING THRU STARBUCKS PER REDLINE ON SITE, WATER TEST OK
PROVIDE 3X2 REDUCERS AT ALL COMBINATION WASTE & VENT
P-TRAPS PER DETAIL FOR FLOOR SINKS. 3/4 HOT & COLD TO STARBUCKS BELOW GRADE OK
07/22/2008 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
CONTRACTOR CANCELED
07/17/2008 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
CAP OF DEMO FLOOR SINK AND MOVE OF FLOOR SINK AND CONTINUATION OF VENT PER INITIAL ON PAGE MP-101 OK

STARBUCKS HAS FIXTURES THAT WOULD BE REQUIRED TO BE DIRECTLY CONNECTED TO SANITARY DRAINS, ONLY INDIRECT DRAINS ARE SHOWN ON APPROVED PLANS. COMBINATION WASTE AND VENT TRAPS NEED TO FOLLOW DETAIL 2 MP-601
FOR REDUCING TAILPIECE & FIXTURE SIZE. INSTALL PER PLAN FOR SIZING
07/10/2008 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
DWV FOR FLOOR SINK AT FLORAL WITH UNDERSLAB WATER LINES OK
DWV FOR FLOOR SINK AT LINE 16 SOUTH PER INITIAL MP-101 OK
07/09/2008 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
2" ABS SLEEVE FOR HELIUM PIPING INSTALLED
UNDERGROUND FOR FLOOR SINKS (2) 3" PER INITIAL MP-101 WATER TEST OK

VENT FOR FLORAL FLOOR SINK IS REQUIRED TO TAKE OFF ABOVE WEIR OF P-TRAP