Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T08CM01828

Parcel: 133033000

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T08CM01828

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
04/12/2010 PLUMBING - FINAL Approved IVRS - Inspection :*
04/05/2010 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) VACUUM BREAKERS AT HAND HELD SHOWERS
2) PROVIDE MACHINE SCREWS FOR MACHINE THREADED CLEANOUT PLUGS
3) LABEL ELECTRICAL PANELS FOR NON METALLIC PIPING
4) CAULK AND CLIP SINKS
5) KINKED CONDENSATE HOSE
03/30/2010 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) CAULK SINKS AS REQUIRED PER INSTALLATION INSTRUCTIONS
2) SUPPORT DW HOSES WITH AN APPROVED CLAMP
3) INSTALL DW HAMMVER ARRESTORS PER PLAN-HB VACUUM BREAKERS
4) WILL WALK ALL UNITS WHEN READY
03/26/2010 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
01/29/2010 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) SINK CLIPS
2) STERILIZATION
3) MACHINE SCREWS AT CLEANOUT PLUGS
4) VACUUM BREAKERS AT HAND HELD SHOW HEADS OPEN TRAP PRIMER VALVES
5) PRE WALK THRU ONLY, STILL NEED TO INSPECT ALL UNITS AND NEED SITE SEWER APPROVAL