Permit: T08CM01713

Parcel: 125081150

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T08CM01713

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
07/02/2008 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
06/06/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK TO COVER ALL AREAS
NEED TO SEE CLOSET FLANGES
06/05/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. SUPPORT ALL WATER STUB-OUTS
2. ONLY 1/3 OF TOTAL DEVELOPED LENGTH OF ANY REQ'D VENT MAY BE RUN IN THE HORIZONTAL POSITION 2"=40'
3. NEED TO SEE CLOSET FLANGES
4. ISOLATE ABS FROM METAL STUDS