Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T08CM01713
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/02/2008 | PLUMBING - ROUGH, SOIL | Approved | ||
05/30/2008 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1. REQUIRE AN APPROVED STAMPED PLAN - FOUND IT 2. NOT INSTALLED PER PLAN 3. PLAN SHOWS "EXISTING" 2" DRAIN WHICH APPEARS TO BE NEW - CONNECTED TO ABS IN THE WALL TO AN ABOVE CEILING INDIRECT WASTE RECEPTOR MADE OUT OF PLUMBING FITTINGS. PROVIDE INSPECTION HISTORY FOR THIS WORK 4. NO TEST ON THE SYSTEM NOTE: A SANTEE IS NOT APPROVED TO BE LAYED ON ITS BACK FOR DRAINAGE PIPING EVEN FOR TEST FITTING NEXT TIME OK TO COVER UNDERGROUND |